TitleChromium determination in osteoblast-like cell culture medium by catalytic cathodic stripping voltammetry with a mercury microelectrode
Publication TypeJournal Article
1998
AuthorsMorais, S, De Carvalho, GS, Sousa, JP
JournalJournal of Trace Elements in Medicine and BiologyJ. Trace Elem. Med. Biol.
Volume12
Issue2
Pagination101 - 108
Date Published1998///
0946672X (ISSN)
Acetates, animal cell, Animalia, Animals, article, atomic absorption spectrometry, Bone Marrow Cells, catalysis, Cell culture, Cells, Cultured, Chromium, complex formation, controlled study, Culture Media, culture medium, drug determination, electrochemistry, Electrodes, Hydrogen-Ion Concentration, in vitro study, Kinetics, Mercury, microelectrode, Microelectrodes, Nitrates, nonhuman, osteoblast, Osteoblasts, potentiometry, priority journal, Rabbits, Reproducibility of Results, sensitivity and specificity, Stromal Cells, technique
A catalytic cathodic stripping voltammetric procedure for the determination of total chromium in osteoblast-like cell culture medium using a mercury film microelectrode (MFM) was optimised. The method is based on the pre-concentration of the Cr(III)-diethylenetriaminepentaacetic acid (DTPA) complex by adsorption at the potential of -1.00 V (vs. Ag/AgCl) in the presence of 10 x 10